| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 11:48:08 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
54 |
07/03/2026 17:02:01 |
|
1702 |
Elevator Failure Start timeout
|
33 |
09/03/2026 15:48:56 |
|
1117 |
Elevator Failure KMI stop switch active
|
28 |
28/02/2026 21:01:17 |
|
1055 |
Elevator Failure Safety circuit: power supply voltage out of 10 % range
|
20 |
13/02/2026 08:17:04 |
|
1094 |
Elevator Failure Induced noise in landing door contact |
17 |
23/02/2026 07:56:56 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
14 |
09/03/2026 15:38:16 |
|
1607 |
Elevator Failure Reopen device active too long
|
14 |
15/02/2026 20:55:10 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
12 |
20/02/2026 18:26:31 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
11 |
28/02/2026 21:01:42 |
|
1606 |
Elevator Failure Car door closing failed, too many closing trials
|
10 |
09/03/2026 12:57:41 |
|
1703 |
Elevator Failure Start failed
|
10 |
28/02/2026 21:11:31 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
10 |
28/02/2026 21:01:34 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
10 |
28/02/2026 21:01:34 |
|
1056 |
Elevator Failure Safety circuit: power supply voltage out of 15 % range
|
8 |
13/02/2026 08:17:04 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
8 |
28/02/2026 20:57:23 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
04/02/2026 15:43:51 |
|
1099 |
Elevator Failure Main stop switch open |
8 |
28/02/2026 20:57:23 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
6 |
09/03/2026 15:53:19 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
6 |
28/02/2026 22:04:53 |
|
1614 |
Elevator Failure Car door close end limit stuck
|
5 |
28/02/2026 20:54:00 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
04/02/2026 15:39:08 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
4 |
04/02/2026 15:40:11 |
|
1181 |
Elevator Failure Door bypass switch misuse |
4 |
28/02/2026 20:54:40 |
|
101 |
Real Alarm Real Alarm |
2 |
28/02/2026 20:20:09 |
|
1037 |
Elevator Failure Car door: stuck contact
|
2 |
28/02/2026 20:50:29 |
|
1830 |
Elevator Failure LON communication error
|
2 |
17/01/2026 11:43:29 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
28/02/2026 20:21:12 |
|
1066 |
Elevator Failure TTS2 communication fault |
1 |
28/02/2026 20:42:09 |