| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 21:51:18 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
45 |
05/03/2026 16:19:29 |
|
1607 |
Elevator Failure Reopen device active too long
|
8 |
01/02/2026 17:00:20 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
8 |
02/01/2026 20:12:19 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
4 |
02/01/2026 19:00:03 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
04/03/2026 09:05:01 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
21/02/2026 12:45:36 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
21/02/2026 12:45:36 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
3 |
02/01/2026 20:43:00 |
|
102 |
Temporary Fault Test Alarm |
2 |
25/02/2026 08:41:08 |
|
1830 |
Elevator Failure LON communication error
|
2 |
21/02/2026 12:45:17 |