Suivi Activite Telesurveillance 43213864


Infos Telalarme
N° Transmetteur 43213864
N° Equipement 43213864
Voie
N° de ligne telephonique 882397171359068
Equipements sur la meme ligne Telephonique 43213864,
Modele et profil TS KCE - DEFAULT
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 19:48:58
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 168
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 93 09/03/2026 20:48:41
1002 Elevator Failure Serial communication broken on board (TTS-1) 52 06/03/2026 15:42:15
1003 Elevator Failure Serial communication broken on board (TTS-2) 52 20/12/2025 16:26:46
1607 Elevator Failure Reopen device active too long 23 04/03/2026 15:50:23
4018 Elevator Failure KCEAPM has no connection to KCECPU 18 13/12/2025 11:51:47
1008 Elevator Failure Safety circuit: Safety gear (C2) 8 06/03/2026 15:42:06
1091 Elevator Failure Lift on final limit magnet 6 06/03/2026 15:39:09
1024 Elevator Failure Hoistway door bypass switch active 5 06/03/2026 15:42:17
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 4 16/12/2025 10:42:42
1068 Elevator Failure 24V power supply voltage out of +- 20 % range 4 06/03/2026 15:42:06
1099 Elevator Failure Main stop switch open 4 06/03/2026 15:42:06
1117 Elevator Failure KMI stop switch active 4 06/03/2026 15:42:15
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 4 06/03/2026 16:44:30
1011 Elevator Failure Car door contact opened during drive (C5) 3 12/12/2025 12:41:07
1031 Elevator Failure Safety circuit: Landing door opened during drive 2 12/12/2025 12:41:07
1066 Elevator Failure TTS2 communication fault 2 18/12/2025 15:19:44
1702 Elevator Failure Start timeout 2 03/01/2026 19:18:16
1830 Elevator Failure LON communication error 2 01/02/2026 03:53:31
1839 Elevator Failure KCEMSC missing from TTS-1 2 01/02/2026 03:53:47
1840 Elevator Failure KCEMSC missing from TTS-2 2 01/02/2026 03:53:47
2000 Elevator Failure Missing COP 2 08/03/2026 10:45:13
100 Temporary Fault Unclassified Alarm 1 25/02/2026 14:19:24
103 False Alarm False Alarm 1 16/02/2026 15:41:25
<-- Retour KOF