Suivi Activite Telesurveillance 43215690


Infos Telalarme
N° Transmetteur 43215690
N° Equipement 43215690
Voie
N° de ligne telephonique 882398937092971
Equipements sur la meme ligne Telephonique 43215690,
Modele et profil TS KCE - DEFAULT KONE 4G
Statut TS BAVARDE
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 05:33:45
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 924
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1132 Elevator Failure Pit inspection mode reset input active too long 1654 09/02/2026 07:17:04
SYSRCA Réception Appel Cyclique 104 09/03/2026 05:18:54
1703 Elevator Failure Start failed 38 16/02/2026 11:31:10
1607 Elevator Failure Reopen device active too long 31 06/03/2026 07:11:00
1099 Elevator Failure Main stop switch open 25 23/01/2026 12:02:41
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 20 16/02/2026 11:41:15
1606 Elevator Failure Car door closing failed, too many closing trials 20 16/02/2026 11:20:16
1023 Elevator Failure Car door bypass switch active 18 23/01/2026 12:03:01
1024 Elevator Failure Hoistway door bypass switch active 18 16/02/2026 11:59:00
1031 Elevator Failure Safety circuit: Landing door opened during drive 16 23/01/2026 12:48:45
1129 Elevator Failure Inspection drive unit stop button active 16 23/01/2026 12:04:35
1068 Elevator Failure 24V power supply voltage out of +- 20 % range 15 23/01/2026 12:02:32
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 11 26/02/2026 10:22:37
1181 Elevator Failure Door bypass switch misuse 8 16/02/2026 11:37:45
1702 Elevator Failure Start timeout 8 15/02/2026 23:54:08
1117 Elevator Failure KMI stop switch active 6 16/02/2026 11:32:40
1004 Elevator Failure TTS serial communication broken. One channel 4 23/01/2026 11:55:36
1011 Elevator Failure Car door contact opened during drive (C5) 4 10/12/2025 15:48:20
4018 Elevator Failure KCEAPM has no connection to KCECPU 3 26/02/2026 10:38:14
102 Temporary Fault Test Alarm 2 16/02/2026 11:34:42
103 False Alarm False Alarm 1 16/02/2026 09:02:03
<-- Retour KOF