Suivi Activite Telesurveillance 43232690


Infos Telalarme
N° Transmetteur 43232690
N° Equipement 43232690
Voie
N° de ligne telephonique 882397104194617
Equipements sur la meme ligne Telephonique 43232690,
Modele et profil TS KCE - DEFAULT
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 16:55:27
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 142
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 95 09/03/2026 17:55:20
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 47 16/02/2026 09:24:16
1031 Elevator Failure Safety circuit: Landing door opened during drive 20 16/02/2026 09:32:24
1011 Elevator Failure Car door contact opened during drive (C5) 18 13/02/2026 14:35:38
1129 Elevator Failure Inspection drive unit stop button active 13 16/02/2026 09:35:42
1607 Elevator Failure Reopen device active too long 10 27/01/2026 16:55:49
1091 Elevator Failure Lift on final limit magnet 8 16/02/2026 09:28:41
1132 Elevator Failure Pit inspection mode reset input active too long 7 16/02/2026 09:23:53
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 6 02/03/2026 16:49:17
1109 Elevator Failure Landing door not opened after top of car inspection 4 16/02/2026 09:35:21
1114 Elevator Failure Pit inspection mode input failure 4 13/02/2026 12:05:13
1702 Elevator Failure Start timeout 4 13/02/2026 17:18:06
1000 Elevator Failure Serial communication broken on board (both TTS channels) 2 13/02/2026 12:53:12
1010 Elevator Failure Safety circuit: blocking device (C4) 2 16/02/2026 09:31:33
102 Temporary Fault Test Alarm 2 16/02/2026 09:34:00
200 System failure: KCE System failure: KCE 2 23/12/2025 21:35:03
4017 Elevator Failure KCEAPM 12V power failed (battery failure) 2 13/02/2026 13:57:25
4018 Elevator Failure KCEAPM has no connection to KCECPU 2 24/12/2025 10:14:25
1003 Elevator Failure Serial communication broken on board (TTS-2) 1 13/02/2026 12:53:12