Suivi Activite Telesurveillance 43237489


Infos Telalarme
N° Transmetteur 43237489
N° Equipement 43237489
Voie
N° de ligne telephonique 882396869361425
Equipements sur la meme ligne Telephonique 43237489,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 05:42:07
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 332
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1094 Elevator Failure Induced noise in landing door contact 151 14/02/2026 12:29:11
SYSRCA Réception Appel Cyclique 99 09/03/2026 06:42:02
1002 Elevator Failure Serial communication broken on board (TTS-1) 74 08/03/2026 18:34:34
1607 Elevator Failure Reopen device active too long 65 12/02/2026 11:14:41
1091 Elevator Failure Lift on final limit magnet 52 04/03/2026 16:16:15
1702 Elevator Failure Start timeout 52 13/02/2026 09:04:21
1106 Elevator Failure Setup failed 48 04/03/2026 16:21:15
1703 Elevator Failure Start failed 28 13/02/2026 14:33:21
1129 Elevator Failure Inspection drive unit stop button active 25 04/03/2026 16:52:12
1031 Elevator Failure Safety circuit: Landing door opened during drive 24 13/02/2026 14:33:25
2000 Elevator Failure Missing COP 23 27/02/2026 10:57:23
2309 Elevator Failure Magnet upside down 20 04/03/2026 16:21:14
4018 Elevator Failure KCEAPM has no connection to KCECPU 18 04/03/2026 17:43:52
1004 Elevator Failure TTS serial communication broken. One channel 15 04/03/2026 15:04:28
1840 Elevator Failure KCEMSC missing from TTS-2 13 04/03/2026 15:04:20
2339 Elevator Failure KCEDZS 24 V power supply failure 12 04/03/2026 16:41:33
1839 Elevator Failure KCEMSC missing from TTS-1 11 04/03/2026 15:04:20
1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range 10 14/02/2026 11:24:48
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 9 04/03/2026 17:42:17
1011 Elevator Failure Car door contact opened during drive (C5) 8 13/02/2026 14:08:09
1044 Elevator Failure Drive not OK 8 04/03/2026 14:55:36
1068 Elevator Failure 24V power supply voltage out of +- 20 % range 8 04/03/2026 14:54:46
1117 Elevator Failure KMI stop switch active 8 04/03/2026 14:45:00
1012 Elevator Failure Rear car door contact opened during drive (C6) 5 26/02/2026 12:58:45
1161 Elevator Failure KCEDZS board failure - Self check failed 5 04/03/2026 16:41:33
1000 Elevator Failure Serial communication broken on board (both TTS channels) 4 04/03/2026 14:55:31
1003 Elevator Failure Serial communication broken on board (TTS-2) 4 04/03/2026 14:55:30
1037 Elevator Failure Car door: stuck contact 4 14/02/2026 11:11:14
1099 Elevator Failure Main stop switch open 4 04/03/2026 14:52:41
1606 Elevator Failure Car door closing failed, too many closing trials 4 20/12/2025 13:10:06
1820 Elevator Failure Drive communication broken 4 04/03/2026 14:55:31
1113 Elevator Failure TTS communication stuck 3 04/03/2026 14:55:39
100 Temporary Fault Unclassified Alarm 2 15/02/2026 12:31:38
1109 Elevator Failure Landing door not opened after top of car inspection 2 04/03/2026 15:18:34
1799 Elevator Failure Self check mode stuck. 2 04/03/2026 14:54:56
102 Temporary Fault Test Alarm 1 13/02/2026 15:08:16
1066 Elevator Failure TTS2 communication fault 1 26/02/2026 12:54:44
<-- Retour KOF