Suivi Activite Telesurveillance 43238225


Infos Telalarme
N° Transmetteur 43238225
N° Equipement 43238225
Voie
N° de ligne telephonique 882396861779279
Equipements sur la meme ligne Telephonique 43238225,
Modele et profil TS KCE - DEFAULT
Statut TS BAVARDE
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 20:31:19
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 2282
Option contrat "Lien vocal" Inclus
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1011 Elevator Failure Car door contact opened during drive (C5) 2335 09/03/2026 21:30:16
1031 Elevator Failure Safety circuit: Landing door opened during drive 2333 09/03/2026 21:30:16
1607 Elevator Failure Reopen device active too long 513 07/03/2026 13:41:51
1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8) 313 04/03/2026 09:06:17
1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7) 179 03/03/2026 10:01:41
1614 Elevator Failure Car door close end limit stuck 120 03/03/2026 15:06:27
1702 Elevator Failure Start timeout 92 26/02/2026 20:24:17
SYSRCA Réception Appel Cyclique 92 09/03/2026 09:41:13
1161 Elevator Failure KCEDZS board failure - Self check failed 55 22/12/2025 16:06:51
1129 Elevator Failure Inspection drive unit stop button active 50 10/01/2026 12:34:37
1132 Elevator Failure Pit inspection mode reset input active too long 49 12/02/2026 08:33:31
1024 Elevator Failure Hoistway door bypass switch active 40 19/02/2026 10:15:03
1703 Elevator Failure Start failed 35 27/02/2026 04:43:38
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 35 08/03/2026 13:20:10
4018 Elevator Failure KCEAPM has no connection to KCECPU 26 17/02/2026 22:41:09
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 24 08/01/2026 11:17:33
2337 Elevator Failure KCEDZS board failure - Faulty magnet sensor 19 21/12/2025 11:16:03
1140 Elevator Failure Safety circuit: Inspection up limit 16 19/02/2026 11:24:14
2353 Elevator Failure Inconsistent magnet reading 9 22/12/2025 16:07:15
1004 Elevator Failure TTS serial communication broken. One channel 7 02/02/2026 07:55:11
1012 Elevator Failure Rear car door contact opened during drive (C6) 7 06/02/2026 13:15:42
1009 Elevator Failure Safety circuit: Emergency exit (C3) 6 07/02/2026 08:38:16
1839 Elevator Failure KCEMSC missing from TTS-1 6 02/02/2026 07:55:03
1840 Elevator Failure KCEMSC missing from TTS-2 5 02/02/2026 07:55:03
1181 Elevator Failure Door bypass switch misuse 4 04/01/2026 08:45:29
1035 Elevator Failure Unintended movement 3 22/12/2025 15:49:03
100 Temporary Fault Unclassified Alarm 1 19/12/2025 17:36:51
103 False Alarm False Alarm 1 08/03/2026 09:49:28
1106 Elevator Failure Setup failed 1 22/12/2025 16:00:02