Suivi Activite Telesurveillance 43238351


Infos Telalarme
N° Transmetteur 43238351
N° Equipement 43238351
Voie
N° de ligne telephonique 882397104350633
Equipements sur la meme ligne Telephonique 43238351,
Modele et profil TS KCE - DEFAULT
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 13:07:20
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 141
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 93 09/03/2026 14:07:13
1002 Elevator Failure Serial communication broken on board (TTS-1) 54 09/03/2026 06:43:48
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 20 06/03/2026 14:36:54
1031 Elevator Failure Safety circuit: Landing door opened during drive 16 06/03/2026 14:56:35
1607 Elevator Failure Reopen device active too long 14 28/02/2026 20:37:00
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 7 06/03/2026 15:59:11
1009 Elevator Failure Safety circuit: Emergency exit (C3) 4 06/03/2026 14:47:00
1010 Elevator Failure Safety circuit: blocking device (C4) 4 06/03/2026 14:47:04
1011 Elevator Failure Car door contact opened during drive (C5) 4 06/03/2026 14:49:23
1012 Elevator Failure Rear car door contact opened during drive (C6) 4 06/03/2026 14:49:32
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 4 06/03/2026 14:48:21
1068 Elevator Failure 24V power supply voltage out of +- 20 % range 4 06/03/2026 14:44:17
1129 Elevator Failure Inspection drive unit stop button active 4 06/03/2026 14:47:10
1132 Elevator Failure Pit inspection mode reset input active too long 4 06/03/2026 14:35:51
1830 Elevator Failure LON communication error 4 19/02/2026 13:40:12
1839 Elevator Failure KCEMSC missing from TTS-1 4 19/02/2026 13:40:26
1840 Elevator Failure KCEMSC missing from TTS-2 4 19/02/2026 13:40:26
1099 Elevator Failure Main stop switch open 3 06/03/2026 14:44:16
1190 Elevator Failure Device picked input dropped while lift running 3 06/03/2026 14:44:16
103 False Alarm False Alarm 2 06/03/2026 14:39:32
4018 Elevator Failure KCEAPM has no connection to KCECPU 2 06/03/2026 15:41:24