1006 |
Elevator Failure TTS line failure |
138 |
02/01/2026 18:18:56 |
| SYSRCA |
|
Réception Appel Cyclique |
101 |
10/03/2026 01:10:38 |
|
1000 |
Elevator Failure Serial communication broken on board (both TTS channels)
|
66 |
17/02/2026 12:38:37 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
65 |
16/02/2026 16:11:42 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
47 |
16/02/2026 13:34:38 |
|
1214 |
Elevator Failure Jumper failure on KCECCG KCEAPS connector
|
39 |
02/01/2026 12:05:16 |
|
4015 |
Elevator Failure Alarm button is stuck
|
37 |
28/01/2026 06:25:34 |
|
1607 |
Elevator Failure Reopen device active too long
|
20 |
26/02/2026 09:41:18 |
|
1003 |
Elevator Failure Serial communication broken on board (TTS-2)
|
14 |
17/02/2026 11:52:52 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
10 |
17/02/2026 11:52:53 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
9 |
30/01/2026 10:14:06 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
9 |
13/02/2026 13:52:03 |
|
1099 |
Elevator Failure Main stop switch open |
8 |
30/01/2026 10:14:05 |
|
1799 |
Elevator Failure Self check mode stuck.
|
6 |
28/01/2026 12:07:00 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
6 |
28/01/2026 12:07:00 |
|
1114 |
Elevator Failure Pit inspection mode input failure |
5 |
13/02/2026 11:41:03 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
5 |
28/01/2026 12:07:00 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
4 |
28/01/2026 12:07:09 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
4 |
17/02/2026 14:01:23 |
|
1062 |
Elevator Failure KCEMSC board failure - No reciprocal communication
|
4 |
28/01/2026 12:06:57 |
|
1161 |
Elevator Failure KCEDZS board failure - Self check failed
|
4 |
02/01/2026 09:09:38 |
|
1167 |
Elevator Failure Board changed after setup
|
4 |
17/02/2026 12:39:46 |
|
1175 |
Elevator Failure Safety system in Safe mode
|
4 |
28/01/2026 12:06:57 |
|
200 |
System failure: KCE System failure: KCE |
4 |
12/12/2025 11:39:49 |
|
2000 |
Elevator Failure Missing COP
|
4 |
17/02/2026 11:53:01 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
4 |
08/02/2026 17:01:49 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
3 |
17/02/2026 13:58:04 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
3 |
13/02/2026 12:47:31 |
|
1182 |
Elevator Failure KCEMSC configuration failure - DIP position changed
|
3 |
13/02/2026 12:47:31 |
|
2342 |
Elevator Failure KCEDZS board failure - Reciprocal communication |
3 |
02/01/2026 09:10:43 |
|
2355 |
Elevator Failure KCEDZS board failure - variant detection |
3 |
02/01/2026 09:09:39 |
|
2384 |
Elevator Failure KCEDZS board failure - Test input |
3 |
02/01/2026 09:10:37 |
|
4017 |
Elevator Failure KCEAPM 12V power failed (battery failure)
|
3 |
17/02/2026 12:52:52 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
2 |
28/01/2026 13:42:40 |
|
1035 |
Elevator Failure Unintended movement
|
2 |
28/01/2026 12:06:57 |
|
1054 |
Elevator Failure Safety circuit: ground fault
|
2 |
28/01/2026 13:42:40 |
|
1188 |
Elevator Failure Safety circuit: Buffers up input (H7) |
2 |
13/02/2026 12:47:31 |
|
2340 |
Elevator Failure KCEDZS board failure - 5 V power supply |
2 |
02/01/2026 09:09:51 |
|
2341 |
Elevator Failure KCEDZS board failure - 3.3 V power supply |
2 |
02/01/2026 09:09:49 |
|
2349 |
Elevator Failure KCEDZS Setup data lost |
2 |
17/02/2026 12:39:40 |
|
1033 |
Elevator Failure safety circuit: Buffers supervision. Up input failure
|
1 |
13/02/2026 12:39:52 |
|
2339 |
Elevator Failure KCEDZS 24 V power supply failure |
1 |
02/01/2026 09:11:52 |