Suivi Activite Telesurveillance 43287768


Infos Telalarme
N° Transmetteur 43287768
N° Equipement 43287768
Voie
N° de ligne telephonique 882397104773845
Equipements sur la meme ligne Telephonique 43287768,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 12:54:33
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 158
Option contrat "Lien vocal" Inclus service loc et com mob.
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 93 09/03/2026 13:54:26
1031 Elevator Failure Safety circuit: Landing door opened during drive 36 11/01/2026 10:33:02
1607 Elevator Failure Reopen device active too long 32 09/03/2026 10:22:21
1011 Elevator Failure Car door contact opened during drive (C5) 28 11/01/2026 10:33:02
1702 Elevator Failure Start timeout 9 24/02/2026 12:31:17
1024 Elevator Failure Hoistway door bypass switch active 7 11/12/2025 13:07:41
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 4 28/01/2026 13:39:44
1091 Elevator Failure Lift on final limit magnet 3 22/12/2025 10:16:27
1703 Elevator Failure Start failed 3 24/02/2026 12:31:33
1606 Elevator Failure Car door closing failed, too many closing trials 2 10/01/2026 22:52:21
1830 Elevator Failure LON communication error 2 05/01/2026 02:36:15
1839 Elevator Failure KCEMSC missing from TTS-1 2 05/01/2026 02:36:34
1840 Elevator Failure KCEMSC missing from TTS-2 2 05/01/2026 02:36:34
4018 Elevator Failure KCEAPM has no connection to KCECPU 2 28/01/2026 14:03:22
100 Temporary Fault Unclassified Alarm 1 23/02/2026 17:01:46
1008 Elevator Failure Safety circuit: Safety gear (C2) 1 22/12/2025 10:15:43
102 Temporary Fault Test Alarm 1 22/12/2025 10:13:30
1070 Elevator Failure Sequential brake dropping fault 1 28/01/2026 10:59:00
<-- Retour KOF