Suivi Activite Telesurveillance 43290960


Infos Telalarme
N° Transmetteur 43290960
N° Equipement 43290960
Voie
N° de ligne telephonique 882397111076780
Equipements sur la meme ligne Telephonique 43290960,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 21:36:55
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 155
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 93 09/03/2026 12:41:21
1607 Elevator Failure Reopen device active too long 28 09/03/2026 16:58:38
1011 Elevator Failure Car door contact opened during drive (C5) 26 02/03/2026 13:44:25
1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8) 26 27/02/2026 15:44:40
1141 Elevator Failure Safety circuit: Inspection down limit 24 27/02/2026 15:43:41
1188 Elevator Failure Safety circuit: Buffers up input (H7) 16 27/02/2026 15:44:55
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 15 27/02/2026 15:44:49
1039 Elevator Failure Door open monitoring functioned 14 27/02/2026 15:38:40
1702 Elevator Failure Start timeout 14 02/03/2026 13:41:48
1008 Elevator Failure Safety circuit: Safety gear (C2) 8 13/01/2026 16:23:46
1839 Elevator Failure KCEMSC missing from TTS-1 6 12/02/2026 19:02:56
1004 Elevator Failure TTS serial communication broken. One channel 4 29/12/2025 19:20:13
1024 Elevator Failure Hoistway door bypass switch active 4 29/12/2025 19:20:57
1031 Elevator Failure Safety circuit: Landing door opened during drive 4 27/02/2026 15:38:40
1034 Elevator Failure safety circuit: Buffers supervision. Down input failure 4 27/02/2026 15:44:02
1109 Elevator Failure Landing door not opened after top of car inspection 4 27/02/2026 15:46:23
1140 Elevator Failure Safety circuit: Inspection up limit 4 29/12/2025 19:22:22
1830 Elevator Failure LON communication error 4 12/02/2026 19:02:39
1840 Elevator Failure KCEMSC missing from TTS-2 3 12/02/2026 19:02:56
1023 Elevator Failure Car door bypass switch active 2 29/12/2025 19:22:00
1129 Elevator Failure Inspection drive unit stop button active 2 27/02/2026 15:41:25
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 2 22/02/2026 00:39:22
1703 Elevator Failure Start failed 1 29/12/2025 16:50:38
<-- Retour KOF