Suivi Activite Telesurveillance 43290971


Infos Telalarme
N° Transmetteur 43290971
N° Equipement 43290971
Voie
N° de ligne telephonique 882397129529950
Equipements sur la meme ligne Telephonique 43290971,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 20:09:23
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 196
Option contrat "Lien vocal" Inclus service loc et com mob.
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 94 09/03/2026 21:09:18
1607 Elevator Failure Reopen device active too long 45 27/01/2026 20:01:13
1011 Elevator Failure Car door contact opened during drive (C5) 26 06/03/2026 12:20:32
1004 Elevator Failure TTS serial communication broken. One channel 25 09/03/2026 11:10:43
1031 Elevator Failure Safety circuit: Landing door opened during drive 23 06/03/2026 12:20:32
1839 Elevator Failure KCEMSC missing from TTS-1 21 09/03/2026 11:10:35
1840 Elevator Failure KCEMSC missing from TTS-2 21 09/03/2026 11:10:35
1000 Elevator Failure Serial communication broken on board (both TTS channels) 20 21/01/2026 11:54:26
1002 Elevator Failure Serial communication broken on board (TTS-1) 14 21/01/2026 12:00:47
1181 Elevator Failure Door bypass switch misuse 14 21/01/2026 11:44:30
1068 Elevator Failure 24V power supply voltage out of +- 20 % range 11 16/02/2026 13:40:59
1099 Elevator Failure Main stop switch open 11 16/02/2026 13:40:59
1023 Elevator Failure Car door bypass switch active 10 16/02/2026 13:39:18
1129 Elevator Failure Inspection drive unit stop button active 10 06/03/2026 11:48:25
1024 Elevator Failure Hoistway door bypass switch active 8 21/01/2026 11:29:00
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 8 21/01/2026 11:43:54
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 6 16/02/2026 21:11:24
1820 Elevator Failure Drive communication broken 4 16/02/2026 13:38:09
2000 Elevator Failure Missing COP 4 06/03/2026 12:24:42
1003 Elevator Failure Serial communication broken on board (TTS-2) 3 21/01/2026 11:59:39
1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs 3 21/01/2026 11:58:14
4017 Elevator Failure KCEAPM 12V power failed (battery failure) 3 06/03/2026 13:24:37
2339 Elevator Failure KCEDZS 24 V power supply failure 2 20/01/2026 21:10:44
4018 Elevator Failure KCEAPM has no connection to KCECPU 2 06/03/2026 13:20:25
102 Temporary Fault Test Alarm 1 21/01/2026 12:12:17
103 False Alarm False Alarm 1 22/12/2025 14:09:14
<-- Retour KOF