| SYSRCA |
|
Réception Appel Cyclique |
96 |
09/03/2026 14:15:03 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
50 |
25/02/2026 21:52:15 |
|
1117 |
Elevator Failure KMI stop switch active
|
50 |
02/02/2026 14:24:15 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
42 |
19/02/2026 19:26:18 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
41 |
06/03/2026 15:57:45 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
28 |
22/02/2026 08:55:00 |
|
1106 |
Elevator Failure Setup failed
|
24 |
02/02/2026 14:05:44 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
22 |
02/02/2026 14:14:43 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
21 |
22/02/2026 11:16:59 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
20 |
22/02/2026 11:16:59 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
18 |
02/02/2026 14:41:02 |
|
1082 |
Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs
|
18 |
02/02/2026 13:49:02 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
6 |
02/02/2026 14:41:17 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
6 |
02/02/2026 14:14:57 |
|
1099 |
Elevator Failure Main stop switch open |
6 |
02/02/2026 14:14:57 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
6 |
02/02/2026 15:32:43 |
|
1607 |
Elevator Failure Reopen device active too long
|
5 |
23/02/2026 19:29:41 |
|
1012 |
Elevator Failure Rear car door contact opened during drive (C6)
|
4 |
11/12/2025 15:45:33 |
|
1044 |
Elevator Failure Motor torque supervision counter |
3 |
05/03/2026 23:40:03 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
3 |
16/02/2026 21:11:07 |
|
1000 |
Elevator Failure Serial communication broken on board (both TTS channels)
|
2 |
21/01/2026 15:41:36 |
|
1003 |
Elevator Failure Serial communication broken on board (TTS-2)
|
2 |
21/01/2026 15:41:35 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
2 |
26/02/2026 00:36:20 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
2 |
26/02/2026 00:36:20 |
|
1066 |
Elevator Failure TTS2 communication fault |
2 |
22/02/2026 08:54:56 |
|
2349 |
Elevator Failure KCEDZS Setup data lost |
2 |
18/01/2026 11:11:16 |
|
4017 |
Elevator Failure KCEAPM 12V power failed (battery failure)
|
2 |
21/01/2026 16:46:06 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
08/02/2026 00:40:50 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
1 |
21/01/2026 15:41:36 |
|
103 |
False Alarm False Alarm |
1 |
02/02/2026 14:38:12 |
|
2000 |
Elevator Failure Missing COP
|
1 |
02/02/2026 14:20:36 |