| SYSRCA |
|
Réception Appel Cyclique |
94 |
09/03/2026 22:42:31 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
44 |
21/02/2026 09:54:40 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
20 |
02/02/2026 15:36:21 |
|
1116 |
Elevator Failure KMI safety chain bypass jumper at place
|
20 |
02/02/2026 15:38:16 |
|
1607 |
Elevator Failure Reopen device active too long
|
10 |
10/01/2026 11:23:47 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
8 |
25/02/2026 18:57:53 |
|
1023 |
Elevator Failure Car door bypass switch active
|
4 |
02/02/2026 15:42:29 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
4 |
02/02/2026 15:41:55 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
02/02/2026 16:02:05 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
4 |
02/02/2026 15:43:03 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
02/02/2026 15:34:04 |
|
1099 |
Elevator Failure Main stop switch open |
4 |
02/02/2026 15:34:03 |
|
1830 |
Elevator Failure LON communication error
|
4 |
30/01/2026 18:56:30 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
30/01/2026 18:56:45 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
30/01/2026 18:56:45 |