Suivi Activite Telesurveillance 43328927


Infos Telalarme
N° Transmetteur 43328927
N° Equipement 43328927
Voie
N° de ligne telephonique 882397186590638
Equipements sur la meme ligne Telephonique 43328927,
Modele et profil TS KCE - DEFAULT KONE 4G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 07:53:04
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 140
Option contrat "Lien vocal" Inclus service loc et com mob.
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 97 09/03/2026 08:52:57
1013 Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7) 18 16/01/2026 09:34:43
1141 Elevator Failure Safety circuit: Inspection down limit 17 15/12/2025 16:06:31
1031 Elevator Failure Safety circuit: Landing door opened during drive 16 15/12/2025 16:07:06
1015 Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8) 14 16/01/2026 09:34:44
1129 Elevator Failure Inspection drive unit stop button active 12 16/01/2026 09:33:47
1607 Elevator Failure Reopen device active too long 12 09/02/2026 01:48:02
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 8 16/01/2026 09:40:03
1140 Elevator Failure Safety circuit: Inspection up limit 8 15/12/2025 16:20:17
1091 Elevator Failure Lift on final limit magnet 6 15/12/2025 16:23:27
1004 Elevator Failure TTS serial communication broken. One channel 4 15/12/2025 16:20:34
1008 Elevator Failure Safety circuit: Safety gear (C2) 4 15/12/2025 16:13:18
1024 Elevator Failure Hoistway door bypass switch active 4 15/12/2025 16:16:31
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 4 15/12/2025 16:16:31
1839 Elevator Failure KCEMSC missing from TTS-1 4 07/01/2026 02:55:17
1840 Elevator Failure KCEMSC missing from TTS-2 4 07/01/2026 02:55:17
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 4 27/02/2026 15:38:30
4018 Elevator Failure KCEAPM has no connection to KCECPU 4 27/02/2026 15:40:27
100 Temporary Fault Unclassified Alarm 2 20/02/2026 13:17:42
1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs 2 15/12/2025 16:19:36
1614 Elevator Failure Car door close end limit stuck 2 30/12/2025 03:17:59
1830 Elevator Failure LON communication error 2 07/01/2026 02:55:00
102 Temporary Fault Test Alarm 1 16/01/2026 08:03:17