| SYSRCA |
|
Réception Appel Cyclique |
95 |
10/03/2026 03:11:13 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
13 |
10/02/2026 10:25:32 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
06/01/2026 14:44:30 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
6 |
05/03/2026 10:56:05 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
6 |
05/03/2026 10:56:05 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
4 |
06/01/2026 14:37:47 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
4 |
06/01/2026 14:35:30 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
06/01/2026 14:37:21 |
|
1830 |
Elevator Failure LON communication error
|
4 |
05/03/2026 10:55:51 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
3 |
10/02/2026 10:25:16 |
|
1099 |
Elevator Failure Main stop switch open |
3 |
06/01/2026 14:37:20 |
|
1702 |
Elevator Failure Start timeout
|
2 |
06/01/2026 14:50:28 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
06/01/2026 14:43:49 |