| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 08:14:05 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
41 |
24/02/2026 09:17:56 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
17 |
06/01/2026 15:15:40 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
16 |
24/02/2026 09:17:49 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
12 |
24/02/2026 09:46:07 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
06/01/2026 14:11:03 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
5 |
25/02/2026 08:15:47 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
06/01/2026 14:22:46 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
06/01/2026 14:13:09 |
|
1099 |
Elevator Failure Main stop switch open |
4 |
06/01/2026 14:13:09 |
|
1703 |
Elevator Failure Start failed
|
3 |
24/02/2026 09:45:02 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
3 |
10/02/2026 10:54:05 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
2 |
06/01/2026 14:23:22 |
|
1607 |
Elevator Failure Reopen device active too long
|
2 |
19/02/2026 14:47:16 |
|
1830 |
Elevator Failure LON communication error
|
2 |
25/02/2026 08:15:31 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
06/01/2026 16:15:10 |
|
102 |
Temporary Fault Test Alarm |
1 |
06/01/2026 14:25:34 |