| SYSRCA |
|
Réception Appel Cyclique |
94 |
09/03/2026 11:38:36 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
48 |
02/03/2026 17:25:19 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
24 |
11/12/2025 13:47:49 |
|
1116 |
Elevator Failure KMI safety chain bypass jumper at place
|
20 |
11/12/2025 11:47:01 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
11 |
26/02/2026 07:30:27 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
10 |
11/12/2025 11:55:54 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
8 |
11/12/2025 11:32:55 |
|
1117 |
Elevator Failure KMI stop switch active
|
6 |
10/02/2026 11:06:14 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
6 |
26/02/2026 07:56:05 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
4 |
16/02/2026 08:32:24 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
4 |
16/02/2026 08:32:24 |
|
1181 |
Elevator Failure Door bypass switch misuse |
4 |
11/12/2025 11:45:48 |
|
102 |
Temporary Fault Test Alarm |
1 |
10/02/2026 11:06:49 |