| SYSRCA |
|
Réception Appel Cyclique |
94 |
09/03/2026 11:19:34 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
63 |
05/03/2026 06:27:34 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
40 |
14/01/2026 09:23:55 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
32 |
14/01/2026 09:23:01 |
|
1033 |
Elevator Failure safety circuit: Buffers supervision. Up input failure
|
26 |
14/01/2026 09:23:24 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
26 |
14/01/2026 09:10:05 |
|
1140 |
Elevator Failure Safety circuit: Inspection up limit
|
24 |
14/01/2026 09:21:44 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
20 |
17/12/2025 08:38:00 |
|
1188 |
Elevator Failure Safety circuit: Buffers up input (H7) |
20 |
17/12/2025 08:38:02 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
16 |
17/12/2025 08:57:09 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
9 |
14/01/2026 10:20:23 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
8 |
17/12/2025 08:56:01 |
|
1013 |
Elevator Failure Safety circuit: car top balustrade not down while on normal mode (C7)
|
8 |
17/12/2025 08:56:31 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
8 |
14/01/2026 09:17:13 |
|
1034 |
Elevator Failure safety circuit: Buffers supervision. Down input failure
|
8 |
17/12/2025 08:57:43 |
|
1099 |
Elevator Failure Main stop switch open |
7 |
14/01/2026 09:10:19 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
6 |
14/01/2026 09:10:19 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
6 |
14/01/2026 09:26:21 |
|
1117 |
Elevator Failure KMI stop switch active
|
6 |
17/12/2025 08:45:37 |
|
1181 |
Elevator Failure Door bypass switch misuse |
6 |
17/12/2025 08:32:39 |
|
1702 |
Elevator Failure Start timeout
|
6 |
17/12/2025 08:29:24 |
|
4002 |
Elevator Failure KCEAPM phone line missing
|
6 |
16/01/2026 11:45:00 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
17/12/2025 08:43:08 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
4 |
17/12/2025 08:42:48 |
|
1023 |
Elevator Failure Car door bypass switch active
|
4 |
17/12/2025 08:31:28 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
4 |
17/12/2025 08:42:48 |
|
1161 |
Elevator Failure KCEDZS board failure - Self check failed
|
4 |
12/12/2025 14:05:35 |
|
1607 |
Elevator Failure Reopen device active too long
|
4 |
27/01/2026 08:53:10 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
05/03/2026 02:22:50 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
05/03/2026 02:22:50 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
2 |
17/12/2025 08:38:00 |
|
1830 |
Elevator Failure LON communication error
|
2 |
05/03/2026 02:22:34 |
|
102 |
Temporary Fault Test Alarm |
1 |
17/12/2025 08:27:02 |
|
2337 |
Elevator Failure KCEDZS board failure - Faulty magnet sensor |
1 |
12/12/2025 14:05:35 |