| SYSRCA |
|
Réception Appel Cyclique |
95 |
10/03/2026 01:44:19 |
|
1000 |
Elevator Failure Serial communication broken on board (both TTS channels)
|
55 |
26/02/2026 11:52:00 |
|
1607 |
Elevator Failure Reopen device active too long
|
39 |
08/03/2026 09:45:54 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
30 |
26/02/2026 11:33:51 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
28 |
26/02/2026 12:10:04 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
21 |
26/02/2026 12:09:56 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
18 |
22/01/2026 11:55:20 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
17 |
26/02/2026 11:23:51 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
16 |
07/02/2026 11:09:24 |
|
1099 |
Elevator Failure Main stop switch open |
16 |
26/02/2026 11:29:25 |
|
1117 |
Elevator Failure KMI stop switch active
|
14 |
24/02/2026 08:08:13 |
|
1161 |
Elevator Failure KCEDZS board failure - Self check failed
|
14 |
24/02/2026 05:51:00 |
|
1003 |
Elevator Failure Serial communication broken on board (TTS-2)
|
12 |
26/02/2026 11:53:21 |
|
2337 |
Elevator Failure KCEDZS board failure - Faulty magnet sensor |
9 |
23/02/2026 13:00:25 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
8 |
18/12/2025 11:48:24 |
|
1702 |
Elevator Failure Start timeout
|
8 |
30/01/2026 07:27:46 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
6 |
22/02/2026 18:15:20 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
6 |
26/02/2026 12:33:23 |
|
1106 |
Elevator Failure Setup failed
|
5 |
26/02/2026 12:02:06 |
|
1175 |
Elevator Failure Safety system in Safe mode
|
5 |
23/02/2026 13:00:30 |
|
1040 |
Elevator Failure Drive time supervision
|
4 |
26/02/2026 12:07:04 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
4 |
26/02/2026 11:33:51 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
3 |
26/02/2026 12:51:54 |
|
1035 |
Elevator Failure Unintended movement
|
3 |
23/02/2026 13:00:30 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
3 |
26/02/2026 11:29:25 |
|
1150 |
Elevator Failure Final limit missing
|
3 |
26/02/2026 12:36:58 |
|
2300 |
Elevator Failure KCEDZS internal RFID failure |
3 |
23/02/2026 13:00:25 |
|
2340 |
Elevator Failure KCEDZS board failure - 5 V power supply |
3 |
24/02/2026 03:46:41 |
|
2342 |
Elevator Failure KCEDZS board failure - Reciprocal communication |
3 |
24/02/2026 03:46:41 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
2 |
22/12/2025 16:36:21 |
|
1062 |
Elevator Failure KCEMSC board failure - No reciprocal communication
|
2 |
23/02/2026 13:00:30 |
|
1082 |
Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs
|
2 |
26/02/2026 12:09:52 |
|
1703 |
Elevator Failure Start failed
|
2 |
22/01/2026 11:55:57 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
18/12/2025 11:37:32 |
|
103 |
False Alarm False Alarm |
1 |
29/12/2025 13:43:32 |
|
1799 |
Elevator Failure Self check mode stuck.
|
1 |
23/02/2026 13:00:32 |
|
2341 |
Elevator Failure KCEDZS board failure - 3.3 V power supply |
1 |
22/02/2026 18:13:42 |
|
2343 |
Elevator Failure KCEDZS board failure - 3 V reference voltage |
1 |
22/02/2026 18:15:50 |