| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 05:51:35 |
|
1607 |
Elevator Failure Reopen device active too long
|
43 |
09/03/2026 18:37:12 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
4 |
14/01/2026 15:16:33 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
4 |
06/03/2026 12:04:19 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
4 |
14/01/2026 15:16:33 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
4 |
06/03/2026 12:04:19 |
|
1188 |
Elevator Failure Safety circuit: Buffers up input (H7) |
4 |
06/03/2026 12:04:19 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
4 |
02/02/2026 18:56:17 |
|
103 |
False Alarm False Alarm |
2 |
17/02/2026 15:02:01 |
|
1830 |
Elevator Failure LON communication error
|
2 |
29/01/2026 04:28:16 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
29/01/2026 04:28:31 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
29/01/2026 04:28:31 |