| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 05:53:47 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
36 |
09/03/2026 20:59:17 |
|
1607 |
Elevator Failure Reopen device active too long
|
33 |
09/03/2026 15:07:21 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
6 |
07/01/2026 08:55:25 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
6 |
31/01/2026 23:12:27 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
6 |
31/01/2026 23:12:27 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
4 |
07/01/2026 08:59:58 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
07/01/2026 08:56:56 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
4 |
07/01/2026 08:56:56 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
07/01/2026 08:53:08 |
|
1099 |
Elevator Failure Main stop switch open |
4 |
07/01/2026 08:53:07 |
|
1830 |
Elevator Failure LON communication error
|
4 |
31/01/2026 23:12:12 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
26/12/2025 20:50:44 |