| SYSRCA |
|
Réception Appel Cyclique |
95 |
09/03/2026 23:06:36 |
|
1607 |
Elevator Failure Reopen device active too long
|
75 |
08/03/2026 00:53:04 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
23 |
03/01/2026 12:04:02 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
16 |
17/12/2025 10:19:34 |
|
1702 |
Elevator Failure Start timeout
|
10 |
09/03/2026 11:25:53 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
8 |
03/01/2026 12:04:02 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
17/12/2025 09:55:40 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
8 |
17/12/2025 10:08:04 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
6 |
06/03/2026 23:17:34 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
17/12/2025 09:58:20 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
4 |
17/12/2025 09:58:20 |
|
1613 |
Elevator Failure Car light failed
|
4 |
17/12/2025 09:47:58 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
4 |
26/12/2025 19:59:31 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
3 |
17/12/2025 09:57:28 |
|
1099 |
Elevator Failure Main stop switch open |
2 |
17/12/2025 09:57:28 |
|
1703 |
Elevator Failure Start failed
|
2 |
17/12/2025 10:18:09 |
|
102 |
Temporary Fault Test Alarm |
1 |
17/12/2025 09:50:11 |
|
103 |
False Alarm False Alarm |
1 |
03/02/2026 16:17:14 |