| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 05:49:58 |
|
1607 |
Elevator Failure Reopen device active too long
|
44 |
10/03/2026 03:51:20 |
|
1099 |
Elevator Failure Main stop switch open |
9 |
04/02/2026 15:04:12 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
8 |
10/02/2026 15:37:30 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
7 |
13/02/2026 15:52:48 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
7 |
13/02/2026 15:52:40 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
7 |
13/02/2026 15:52:40 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
6 |
10/02/2026 15:49:29 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
6 |
04/02/2026 15:04:12 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
6 |
10/02/2026 16:38:14 |
|
1064 |
Elevator Failure Movement risk during start or stop sequence (HW failure) counter |
5 |
29/01/2026 17:15:10 |
|
1043 |
Elevator Failure Start permit fault
|
4 |
04/02/2026 15:15:32 |
|
1614 |
Elevator Failure Car door close end limit stuck
|
4 |
13/02/2026 13:03:54 |
|
1830 |
Elevator Failure LON communication error
|
2 |
01/01/2026 01:52:02 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
2 |
04/02/2026 16:04:35 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
10/02/2026 15:54:42 |