| SYSRCA |
|
Réception Appel Cyclique |
94 |
09/03/2026 07:52:08 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
44 |
04/03/2026 06:25:53 |
|
1012 |
Elevator Failure Rear car door contact opened during drive (C6)
|
24 |
16/02/2026 16:20:15 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
20 |
09/01/2026 09:19:49 |
|
1117 |
Elevator Failure KMI stop switch active
|
20 |
09/01/2026 09:18:27 |
|
1188 |
Elevator Failure Safety circuit: Buffers up input (H7) |
19 |
09/01/2026 09:19:49 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
14 |
09/01/2026 09:19:43 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
9 |
14/02/2026 13:17:27 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
8 |
09/01/2026 09:18:37 |
|
1132 |
Elevator Failure Pit inspection mode reset input active too long |
8 |
09/01/2026 09:19:07 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
8 |
28/02/2026 02:03:41 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
8 |
28/02/2026 02:03:41 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
4 |
17/01/2026 06:11:56 |
|
1702 |
Elevator Failure Start timeout
|
2 |
13/12/2025 09:38:54 |
|
1830 |
Elevator Failure LON communication error
|
2 |
28/02/2026 02:03:23 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
06/02/2026 11:14:29 |