| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 12:53:09 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
11 |
23/12/2025 09:04:56 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
4 |
23/12/2025 09:15:22 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
4 |
23/12/2025 09:22:49 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
2 |
23/12/2025 09:16:12 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
2 |
23/12/2025 09:03:51 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
2 |
23/12/2025 09:17:34 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
2 |
23/12/2025 09:18:42 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
24/02/2026 19:44:19 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
2 |
23/12/2025 11:11:55 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
1 |
23/12/2025 09:17:03 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
1 |
23/12/2025 09:15:42 |
|
102 |
Temporary Fault Test Alarm |
1 |
05/02/2026 09:11:09 |
|
1099 |
Elevator Failure Main stop switch open |
1 |
23/12/2025 09:17:33 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
1 |
23/12/2025 09:06:03 |
|
1114 |
Elevator Failure Pit inspection mode input failure |
1 |
23/12/2025 09:03:52 |
|
1830 |
Elevator Failure LON communication error
|
1 |
11/02/2026 02:23:42 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
1 |
11/02/2026 02:23:59 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
1 |
11/02/2026 02:23:59 |