| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 06:02:05 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
20 |
21/01/2026 11:44:49 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
18 |
21/01/2026 11:31:33 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
12 |
01/01/2026 06:35:09 |
|
1607 |
Elevator Failure Reopen device active too long
|
10 |
09/02/2026 09:44:18 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
21/01/2026 12:07:16 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
8 |
21/01/2026 12:25:55 |
|
1702 |
Elevator Failure Start timeout
|
6 |
21/01/2026 11:38:28 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
21/01/2026 12:08:14 |
|
1009 |
Elevator Failure Safety circuit: Emergency exit (C3)
|
4 |
21/01/2026 11:42:43 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
4 |
21/01/2026 11:42:27 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
4 |
21/01/2026 11:43:44 |
|
1012 |
Elevator Failure Rear car door contact opened during drive (C6)
|
4 |
21/01/2026 11:43:13 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
4 |
21/01/2026 13:14:59 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
2 |
21/01/2026 11:44:07 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
2 |
21/01/2026 12:14:03 |
|
1099 |
Elevator Failure Main stop switch open |
2 |
21/01/2026 12:14:03 |
|
1703 |
Elevator Failure Start failed
|
2 |
21/01/2026 11:30:15 |
|
1830 |
Elevator Failure LON communication error
|
2 |
30/12/2025 02:33:59 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
30/12/2025 02:34:17 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
30/12/2025 02:34:17 |
|
102 |
Temporary Fault Test Alarm |
1 |
21/01/2026 12:12:39 |