| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 08:26:20 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
53 |
05/03/2026 19:36:52 |
|
1607 |
Elevator Failure Reopen device active too long
|
24 |
08/03/2026 13:45:02 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
14 |
02/02/2026 12:50:16 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
27/01/2026 08:59:39 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
27/01/2026 09:01:51 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
4 |
27/01/2026 09:25:10 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
27/01/2026 09:28:28 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
4 |
27/01/2026 09:07:09 |
|
1037 |
Elevator Failure Car door: stuck contact
|
4 |
02/02/2026 12:50:25 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
4 |
27/01/2026 09:25:18 |
|
1614 |
Elevator Failure Car door close end limit stuck
|
4 |
02/01/2026 17:08:15 |
|
1702 |
Elevator Failure Start timeout
|
2 |
02/02/2026 12:50:29 |
|
1830 |
Elevator Failure LON communication error
|
2 |
11/02/2026 00:37:19 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
11/02/2026 00:37:36 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
23/12/2025 07:34:46 |