| SYSRCA |
|
Réception Appel Cyclique |
89 |
09/03/2026 04:50:00 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
20 |
19/01/2026 11:40:59 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
12 |
27/02/2026 15:09:37 |
|
1607 |
Elevator Failure Reopen device active too long
|
12 |
07/03/2026 12:09:43 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
8 |
27/02/2026 15:19:35 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
6 |
27/02/2026 15:08:39 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
6 |
27/02/2026 15:19:27 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
5 |
27/02/2026 15:19:27 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
5 |
24/02/2026 22:24:07 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
4 |
29/01/2026 16:27:43 |
|
1830 |
Elevator Failure LON communication error
|
2 |
18/01/2026 08:43:19 |
|
1099 |
Elevator Failure Main stop switch open |
1 |
27/02/2026 15:20:01 |
|
1606 |
Elevator Failure Car door closing failed, too many closing trials
|
1 |
24/02/2026 21:08:46 |