| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 06:12:15 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
63 |
09/03/2026 09:26:31 |
|
1607 |
Elevator Failure Reopen device active too long
|
32 |
01/03/2026 17:15:20 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
06/03/2026 11:53:02 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
6 |
23/02/2026 09:07:41 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
6 |
23/02/2026 09:07:41 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
4 |
23/02/2026 09:07:49 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
06/03/2026 11:50:17 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
4 |
20/02/2026 22:30:45 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
06/03/2026 11:53:32 |
|
1099 |
Elevator Failure Main stop switch open |
4 |
06/03/2026 11:53:32 |
|
1830 |
Elevator Failure LON communication error
|
4 |
19/02/2026 11:59:52 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
2 |
20/02/2026 22:30:45 |