| SYSRCA |
|
Réception Appel Cyclique |
94 |
05/03/2026 15:38:30 |
|
4017 |
Elevator Failure KCEAPM 12V power failed (battery failure)
|
50 |
10/02/2026 16:49:51 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
30 |
05/02/2026 04:37:26 |
|
103 |
False Alarm False Alarm |
27 |
05/02/2026 17:02:11 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
24 |
12/02/2026 16:48:55 |
|
1015 |
Elevator Failure Safety circuit: car top balustrade not up while on top of car inspection mode (C8)
|
17 |
05/03/2026 15:05:15 |
|
1039 |
Elevator Failure Door open monitoring functioned
|
17 |
05/03/2026 15:05:15 |
|
100 |
Temporary Fault Unclassified Alarm |
14 |
05/02/2026 16:39:54 |
|
1607 |
Elevator Failure Reopen device active too long
|
12 |
03/03/2026 18:59:14 |
|
1188 |
Elevator Failure Safety circuit: Buffers up input (H7) |
10 |
05/03/2026 15:05:15 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
10/02/2026 14:48:28 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
3 |
10/02/2026 14:48:36 |
|
1023 |
Elevator Failure Car door bypass switch active
|
3 |
10/02/2026 14:20:33 |
|
200 |
System failure: KCE System failure: KCE |
3 |
10/02/2026 14:31:47 |
|
1702 |
Elevator Failure Start timeout
|
2 |
11/02/2026 12:50:45 |
|
1830 |
Elevator Failure LON communication error
|
2 |
28/01/2026 14:44:36 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
28/01/2026 14:44:52 |
|
101 |
Real Alarm Real Alarm |
1 |
05/02/2026 14:41:50 |
|
102 |
Temporary Fault Test Alarm |
1 |