| SYSRCA |
|
Réception Appel Cyclique |
95 |
10/03/2026 03:54:53 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
64 |
09/03/2026 22:03:35 |
|
1607 |
Elevator Failure Reopen device active too long
|
36 |
06/03/2026 09:35:20 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
18 |
05/01/2026 23:53:56 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
16 |
27/01/2026 12:20:51 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
8 |
27/01/2026 11:54:29 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
8 |
27/01/2026 12:21:26 |
|
1702 |
Elevator Failure Start timeout
|
8 |
27/01/2026 11:54:32 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
27/01/2026 10:13:35 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
27/01/2026 13:16:03 |
|
1099 |
Elevator Failure Main stop switch open |
4 |
27/01/2026 13:16:03 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
3 |
23/02/2026 21:54:07 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
3 |
23/02/2026 21:54:07 |
|
1703 |
Elevator Failure Start failed
|
2 |
27/01/2026 12:21:28 |
|
1830 |
Elevator Failure LON communication error
|
2 |
05/01/2026 04:51:16 |
|
4002 |
Elevator Failure KCEAPM phone line missing
|
2 |
31/01/2026 01:25:57 |