| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 09:51:14 |
|
1607 |
Elevator Failure Reopen device active too long
|
18 |
01/03/2026 20:10:17 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
8 |
29/12/2025 15:46:54 |
|
1614 |
Elevator Failure Car door close end limit stuck
|
6 |
29/12/2025 15:44:21 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
03/03/2026 18:41:02 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
29/12/2025 16:01:03 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
4 |
29/12/2025 15:40:57 |
|
1702 |
Elevator Failure Start timeout
|
4 |
29/12/2025 15:48:22 |
|
1830 |
Elevator Failure LON communication error
|
4 |
03/03/2026 14:19:03 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
03/03/2026 14:19:21 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
03/03/2026 14:19:21 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
2 |
29/12/2025 15:47:25 |
|
102 |
Temporary Fault Test Alarm |
1 |
18/01/2026 14:48:21 |
|
103 |
False Alarm False Alarm |
1 |
24/02/2026 17:54:18 |