Suivi Activite Telesurveillance 43511974


Infos Telalarme
N° Transmetteur 43511974
N° Equipement 43511974
Voie
N° de ligne telephonique 882397110388932
Equipements sur la meme ligne Telephonique 43511974,
Modele et profil TS KCE - DEFAULT
Statut TS BAVARDE
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 18:50:32
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 2958
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1110 Elevator Failure Additional 24V measurement failure 4422 19/02/2026 18:05:20
1055 Elevator Failure Safety circuit: power supply voltage out of 10 % range 234 20/02/2026 10:50:49
2000 Elevator Failure Missing COP 191 03/03/2026 01:05:52
1094 Elevator Failure Induced noise in landing door contact 169 02/03/2026 10:39:00
4018 Elevator Failure KCEAPM has no connection to KCECPU 168 03/03/2026 01:24:22
1056 Elevator Failure Safety circuit: power supply voltage out of 15 % range 134 02/03/2026 05:07:27
1109 Elevator Failure Landing door not opened after top of car inspection 106 03/03/2026 01:05:52
SYSRCA Réception Appel Cyclique 94 09/03/2026 19:50:24
1830 Elevator Failure LON communication error 85 03/03/2026 00:24:37
1115 Elevator Failure KCEMSC board failure - Safety input power supply 79 02/03/2026 05:07:28
1607 Elevator Failure Reopen device active too long 41 17/02/2026 22:17:38
1129 Elevator Failure Inspection drive unit stop button active 11 20/02/2026 10:52:35
1703 Elevator Failure Start failed 9 06/02/2026 20:45:31
1840 Elevator Failure KCEMSC missing from TTS-2 9 27/02/2026 10:02:30
1011 Elevator Failure Car door contact opened during drive (C5) 8 16/02/2026 17:40:26
1132 Elevator Failure Pit inspection mode reset input active too long 8 20/02/2026 04:56:25
1839 Elevator Failure KCEMSC missing from TTS-1 8 27/02/2026 10:02:30
1702 Elevator Failure Start timeout 7 19/02/2026 17:59:53
1031 Elevator Failure Safety circuit: Landing door opened during drive 6 06/02/2026 20:36:16
1057 Elevator Failure Safety circuit: power supply voltage out of 20 % range 3 23/02/2026 06:23:10
100 Temporary Fault Unclassified Alarm 2 13/02/2026 10:40:05
1117 Elevator Failure KMI stop switch active 2 06/02/2026 21:30:43
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 2 06/02/2026 23:35:11
1004 Elevator Failure TTS serial communication broken. One channel 1 06/02/2026 21:30:54
101 Real Alarm Real Alarm 1 06/02/2026 20:49:12
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 1 20/02/2026 04:54:23
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 1 20/02/2026 04:54:23