| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 05:45:45 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
70 |
09/03/2026 22:15:05 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
12 |
16/01/2026 10:23:11 |
|
1607 |
Elevator Failure Reopen device active too long
|
12 |
25/02/2026 15:28:25 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
8 |
16/01/2026 10:22:06 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
16/01/2026 10:27:33 |
|
1703 |
Elevator Failure Start failed
|
2 |
16/01/2026 10:25:47 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
25/12/2025 22:53:00 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
03/02/2026 14:29:21 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
2 |
16/02/2026 14:52:30 |
|
1830 |
Elevator Failure LON communication error
|
1 |
25/12/2025 22:52:41 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
1 |
25/12/2025 22:53:00 |