| SYSRCA |
|
Réception Appel Cyclique |
91 |
09/03/2026 10:03:48 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
8 |
06/01/2026 11:38:26 |
|
1607 |
Elevator Failure Reopen device active too long
|
8 |
13/02/2026 15:09:50 |
|
1702 |
Elevator Failure Start timeout
|
8 |
02/03/2026 12:16:03 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
7 |
16/02/2026 09:01:40 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
4 |
17/02/2026 15:33:55 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
17/02/2026 15:33:47 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
17/02/2026 15:33:47 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
4 |
12/02/2026 03:57:20 |
|
1002 |
Elevator Failure Braking resistor supervision |
2 |
13/02/2026 08:11:13 |
|
1613 |
Elevator Failure Car light failed
|
2 |
12/02/2026 01:37:21 |