| SYSRCA |
|
Réception Appel Cyclique |
95 |
09/03/2026 08:24:54 |
|
1607 |
Elevator Failure Reopen device active too long
|
34 |
09/03/2026 06:57:44 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
15 |
05/01/2026 09:04:33 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
10 |
25/02/2026 11:54:49 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
8 |
25/02/2026 11:51:23 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
6 |
25/02/2026 11:38:09 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
6 |
14/02/2026 20:07:08 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
6 |
14/02/2026 20:07:08 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
4 |
25/02/2026 11:42:17 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
4 |
25/02/2026 11:45:46 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
3 |
25/02/2026 11:41:06 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
25/02/2026 13:14:52 |
|
100 |
Temporary Fault Unclassified Alarm |
1 |
25/02/2026 12:12:00 |
|
1009 |
Elevator Failure Safety circuit: Emergency exit (C3)
|
1 |
25/02/2026 11:49:49 |