Suivi Activite Telesurveillance 43525837


Infos Telalarme
N° Transmetteur 43525837
N° Equipement 43525837
Voie
N° de ligne telephonique 882397108173965
Equipements sur la meme ligne Telephonique 43525837, 43525838,
Modele et profil TS KCE - DEFAULT
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 21:48:18
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 165
Option contrat "Lien vocal" Inclus
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
SYSRCA Réception Appel Cyclique 95 09/03/2026 10:14:19
1002 Elevator Failure Serial communication broken on board (TTS-1) 48 05/03/2026 08:51:19
1117 Elevator Failure KMI stop switch active 23 03/02/2026 14:06:04
1011 Elevator Failure Car door contact opened during drive (C5) 14 24/02/2026 12:33:01
1702 Elevator Failure Start timeout 13 23/02/2026 07:26:13
1607 Elevator Failure Reopen device active too long 11 05/03/2026 22:29:40
1004 Elevator Failure TTS serial communication broken. One channel 9 03/02/2026 14:06:08
1840 Elevator Failure KCEMSC missing from TTS-2 9 12/02/2026 04:29:21
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 8 24/12/2025 12:31:46
1839 Elevator Failure KCEMSC missing from TTS-1 8 12/02/2026 04:29:21
1031 Elevator Failure Safety circuit: Landing door opened during drive 6 24/12/2025 12:07:40
200 System failure: KCE System failure: KCE 6 09/03/2026 04:01:34
4017 Elevator Failure KCEAPM 12V power failed (battery failure) 6 08/03/2026 04:39:59
1091 Elevator Failure Lift on final limit magnet 3 24/12/2025 11:11:38
1129 Elevator Failure Inspection drive unit stop button active 3 24/12/2025 12:26:04
1132 Elevator Failure Pit inspection mode reset input active too long 3 24/12/2025 12:34:53
100 Temporary Fault Unclassified Alarm 2 24/12/2025 11:30:27
1008 Elevator Failure Safety circuit: Safety gear (C2) 2 24/12/2025 11:14:52
1010 Elevator Failure Safety circuit: blocking device (C4) 2 24/12/2025 12:06:23
103 False Alarm False Alarm 2 30/01/2026 10:10:52
1830 Elevator Failure LON communication error 2 12/02/2026 04:29:05
2000 Elevator Failure Missing COP 2 24/12/2025 11:28:14
4002 Elevator Failure KCEAPM phone line missing 2 08/03/2026 02:03:22
102 Temporary Fault Test Alarm 1 06/03/2026 14:14:36
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 1 24/12/2025 12:06:40
1062 Elevator Failure KCEMSC board failure - No reciprocal communication 1 24/12/2025 11:23:53
1703 Elevator Failure Start failed 1 24/12/2025 12:32:44
1799 Elevator Failure Self check mode stuck. 1 24/12/2025 11:23:56
2339 Elevator Failure KCEDZS 24 V power supply failure 1 24/12/2025 11:23:47
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 1 24/12/2025 12:26:50
<-- Retour KOF