| SYSRCA |
|
Réception Appel Cyclique |
95 |
09/03/2026 10:14:19 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
48 |
05/03/2026 08:51:19 |
|
1117 |
Elevator Failure KMI stop switch active
|
23 |
03/02/2026 14:06:04 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
14 |
24/02/2026 12:33:01 |
|
1702 |
Elevator Failure Start timeout
|
13 |
23/02/2026 07:26:13 |
|
1607 |
Elevator Failure Reopen device active too long
|
11 |
05/03/2026 22:29:40 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
9 |
03/02/2026 14:06:08 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
9 |
12/02/2026 04:29:21 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
8 |
24/12/2025 12:31:46 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
8 |
12/02/2026 04:29:21 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
6 |
24/12/2025 12:07:40 |
|
200 |
System failure: KCE System failure: KCE |
6 |
09/03/2026 04:01:34 |
|
4017 |
Elevator Failure KCEAPM 12V power failed (battery failure)
|
6 |
08/03/2026 04:39:59 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
3 |
24/12/2025 11:11:38 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
3 |
24/12/2025 12:26:04 |
|
1132 |
Elevator Failure Pit inspection mode reset input active too long |
3 |
24/12/2025 12:34:53 |
|
100 |
Temporary Fault Unclassified Alarm |
2 |
24/12/2025 11:30:27 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
2 |
24/12/2025 11:14:52 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
2 |
24/12/2025 12:06:23 |
|
103 |
False Alarm False Alarm |
2 |
30/01/2026 10:10:52 |
|
1830 |
Elevator Failure LON communication error
|
2 |
12/02/2026 04:29:05 |
|
2000 |
Elevator Failure Missing COP
|
2 |
24/12/2025 11:28:14 |
|
4002 |
Elevator Failure KCEAPM phone line missing
|
2 |
08/03/2026 02:03:22 |
|
102 |
Temporary Fault Test Alarm |
1 |
06/03/2026 14:14:36 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
1 |
24/12/2025 12:06:40 |
|
1062 |
Elevator Failure KCEMSC board failure - No reciprocal communication
|
1 |
24/12/2025 11:23:53 |
|
1703 |
Elevator Failure Start failed
|
1 |
24/12/2025 12:32:44 |
|
1799 |
Elevator Failure Self check mode stuck.
|
1 |
24/12/2025 11:23:56 |
|
2339 |
Elevator Failure KCEDZS 24 V power supply failure |
1 |
24/12/2025 11:23:47 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
1 |
24/12/2025 12:26:50 |