| SYSRCA |
|
Réception Appel Cyclique |
94 |
10/03/2026 02:46:47 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
8 |
02/02/2026 16:25:59 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
02/02/2026 16:25:12 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
02/02/2026 15:57:45 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
02/02/2026 16:26:04 |
|
1099 |
Elevator Failure Main stop switch open |
4 |
02/02/2026 16:26:04 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
4 |
19/02/2026 08:47:43 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
3 |
02/02/2026 17:02:15 |
|
1607 |
Elevator Failure Reopen device active too long
|
2 |
04/02/2026 18:21:07 |
|
1830 |
Elevator Failure LON communication error
|
2 |
25/01/2026 01:07:29 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
25/01/2026 01:07:47 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
25/01/2026 01:07:47 |