| SYSRCA |
|
Réception Appel Cyclique |
91 |
09/03/2026 19:05:57 |
|
1607 |
Elevator Failure Reopen device active too long
|
43 |
09/03/2026 22:39:24 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
8 |
16/02/2026 09:38:51 |
|
1613 |
Elevator Failure Car light failed
|
6 |
08/01/2026 17:42:33 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
16/02/2026 09:20:00 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
16/02/2026 09:39:17 |
|
1099 |
Elevator Failure Main stop switch open |
4 |
16/02/2026 09:39:16 |
|
1830 |
Elevator Failure LON communication error
|
4 |
06/03/2026 14:32:04 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
4 |
06/03/2026 14:32:22 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
06/03/2026 14:32:22 |
|
1702 |
Elevator Failure Start timeout
|
2 |
16/02/2026 10:51:30 |