4002 |
Elevator Failure KCEAPM phone line missing
|
130 |
10/03/2026 00:56:45 |
| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 06:00:29 |
|
1607 |
Elevator Failure Reopen device active too long
|
16 |
25/02/2026 20:17:02 |
|
1099 |
Elevator Failure Main stop switch open |
7 |
31/12/2025 10:45:52 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
7 |
16/01/2026 08:23:06 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
6 |
07/03/2026 00:24:49 |
|
1190 |
Elevator Failure Device picked input dropped while lift running
|
5 |
25/12/2025 11:45:45 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
5 |
07/03/2026 00:24:49 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
5 |
31/12/2025 12:32:55 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
4 |
31/12/2025 11:41:05 |
|
1043 |
Elevator Failure Start permit fault
|
4 |
25/12/2025 11:45:46 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
4 |
31/12/2025 10:45:52 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
4 |
31/12/2025 11:33:09 |
|
1830 |
Elevator Failure LON communication error
|
3 |
07/03/2026 00:24:34 |
|
1007 |
Elevator Failure Motor parameterization fault |
2 |
31/12/2025 11:32:59 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
2 |
31/12/2025 10:49:35 |
|
1702 |
Elevator Failure Start timeout
|
1 |
25/12/2025 10:00:16 |