Suivi Activite Telesurveillance 43610049


Infos Telalarme
N° Transmetteur 43610049
N° Equipement 43610049
Voie
N° de ligne telephonique 882397108170680
Equipements sur la meme ligne Telephonique 43610049,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 23:47:10
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 352
Option contrat "Lien vocal" Inclus
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1607 Elevator Failure Reopen device active too long 149 09/03/2026 12:31:24
SYSRCA Réception Appel Cyclique 95 10/03/2026 00:47:05
1004 Elevator Failure TTS serial communication broken. One channel 46 03/03/2026 16:47:32
1150 Elevator Failure Final limit missing 40 03/03/2026 15:58:21
1106 Elevator Failure Setup failed 37 03/03/2026 15:58:21
1117 Elevator Failure KMI stop switch active 32 03/03/2026 15:44:43
1002 Elevator Failure Serial communication broken on board (TTS-1) 31 08/03/2026 11:12:20
1024 Elevator Failure Hoistway door bypass switch active 30 03/03/2026 15:53:33
1839 Elevator Failure KCEMSC missing from TTS-1 29 03/03/2026 16:47:24
1840 Elevator Failure KCEMSC missing from TTS-2 29 03/03/2026 16:47:24
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 24 06/03/2026 14:23:09
1116 Elevator Failure KMI safety chain bypass jumper at place 20 03/03/2026 14:53:38
1091 Elevator Failure Lift on final limit magnet 15 03/03/2026 14:57:53
1702 Elevator Failure Start timeout 15 25/02/2026 11:00:20
1129 Elevator Failure Inspection drive unit stop button active 13 03/03/2026 15:41:48
1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs 12 25/02/2026 10:57:13
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 10 03/03/2026 16:41:09
1011 Elevator Failure Car door contact opened during drive (C5) 9 17/02/2026 21:12:47
1068 Elevator Failure 24V power supply voltage out of +- 20 % range 9 03/03/2026 15:27:36
1099 Elevator Failure Main stop switch open 8 03/03/2026 15:27:35
1023 Elevator Failure Car door bypass switch active 7 03/03/2026 15:43:47
4018 Elevator Failure KCEAPM has no connection to KCECPU 7 03/03/2026 17:55:40
1181 Elevator Failure Door bypass switch misuse 5 03/03/2026 15:43:56
1012 Elevator Failure Rear car door contact opened during drive (C6) 4 06/02/2026 18:59:35
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 4 25/02/2026 09:14:56
1830 Elevator Failure LON communication error 4 01/02/2026 01:05:50
1066 Elevator Failure TTS2 communication fault 2 03/03/2026 16:47:28
1169 Elevator Failure Linear position failure when moving 2 03/03/2026 15:54:01
1703 Elevator Failure Start failed 2 14/12/2025 12:15:34
2342 Elevator Failure KCEDZS board failure - Reciprocal communication 2 03/03/2026 14:56:10
100 Temporary Fault Unclassified Alarm 1 03/03/2026 17:01:06
1008 Elevator Failure Safety circuit: Safety gear (C2) 1 25/02/2026 09:14:04
102 Temporary Fault Test Alarm 1 11/12/2025 15:40:18