| SYSRCA |
|
Réception Appel Cyclique |
92 |
09/03/2026 08:40:45 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
63 |
05/02/2026 10:00:47 |
|
1106 |
Elevator Failure Setup failed
|
40 |
18/12/2025 14:51:50 |
|
1607 |
Elevator Failure Reopen device active too long
|
32 |
08/03/2026 17:51:25 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
22 |
18/12/2025 09:21:37 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
21 |
18/12/2025 14:57:05 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
18 |
18/12/2025 14:56:57 |
|
1000 |
Elevator Failure Serial communication broken on board (both TTS channels)
|
16 |
18/12/2025 11:00:08 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
16 |
05/02/2026 10:00:39 |
|
1117 |
Elevator Failure KMI stop switch active
|
16 |
18/12/2025 14:56:56 |
|
1161 |
Elevator Failure KCEDZS board failure - Self check failed
|
15 |
15/12/2025 08:14:18 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
15 |
18/12/2025 14:56:57 |
|
1003 |
Elevator Failure Serial communication broken on board (TTS-2)
|
14 |
18/12/2025 11:01:32 |
|
2349 |
Elevator Failure KCEDZS Setup data lost |
14 |
18/12/2025 15:08:10 |
|
1099 |
Elevator Failure Main stop switch open |
9 |
18/12/2025 08:45:23 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
8 |
18/12/2025 09:20:48 |
|
2319 |
Elevator Failure Insufficient magnetic field from position magnet |
8 |
15/12/2025 08:22:39 |
|
1023 |
Elevator Failure Car door bypass switch active
|
7 |
18/12/2025 11:20:03 |
|
1035 |
Elevator Failure Unintended movement
|
7 |
15/12/2025 09:01:29 |
|
1175 |
Elevator Failure Safety system in Safe mode
|
7 |
15/12/2025 09:01:29 |
|
1002 |
Elevator Failure Serial communication broken on board (TTS-1)
|
6 |
18/12/2025 11:00:07 |
|
1062 |
Elevator Failure KCEMSC board failure - No reciprocal communication
|
4 |
15/12/2025 09:01:29 |
|
1082 |
Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs
|
4 |
18/12/2025 11:20:04 |
|
1114 |
Elevator Failure Pit inspection mode input failure |
4 |
18/12/2025 15:50:08 |
|
1799 |
Elevator Failure Self check mode stuck.
|
4 |
18/12/2025 15:00:10 |
|
2000 |
Elevator Failure Missing COP
|
4 |
18/12/2025 09:20:42 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
4 |
18/12/2025 15:59:45 |
|
1063 |
Elevator Failure KCEMSC board failure - Relay K51 feedback
|
3 |
15/12/2025 09:01:29 |
|
1064 |
Elevator Failure KCEMSC board failure - Relay K52 feedback
|
3 |
15/12/2025 09:01:29 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
3 |
15/12/2025 09:01:29 |
|
1066 |
Elevator Failure TTS2 communication fault |
2 |
18/12/2025 11:18:01 |
|
1075 |
Elevator Failure KCEFUI board disconnected
|
2 |
18/12/2025 15:00:07 |
|
1111 |
Elevator Failure KCEFUI SPI failure |
2 |
18/12/2025 15:00:07 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
2 |
18/12/2025 17:09:03 |
|
102 |
Temporary Fault Test Alarm |
1 |
03/02/2026 10:10:56 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
1 |
15/12/2025 08:49:15 |