Suivi Activite Telesurveillance 43745968


Infos Telalarme
N° Transmetteur 43745968
N° Equipement 43745968
Voie
N° de ligne telephonique 882397109053499
Equipements sur la meme ligne Telephonique 43745968,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 15:28:12
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 339
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1703 Elevator Failure Start failed 128 03/01/2026 14:46:22
SYSRCA Réception Appel Cyclique 93 09/03/2026 16:28:07
1702 Elevator Failure Start timeout 92 03/01/2026 11:52:47
1607 Elevator Failure Reopen device active too long 67 26/01/2026 10:06:04
1000 Elevator Failure Serial communication broken on board (both TTS channels) 18 02/02/2026 16:10:55
1614 Elevator Failure Car door close end limit stuck 16 28/02/2026 08:58:24
1003 Elevator Failure Serial communication broken on board (TTS-2) 10 02/02/2026 16:10:58
1840 Elevator Failure KCEMSC missing from TTS-2 7 09/02/2026 16:55:34
1004 Elevator Failure TTS serial communication broken. One channel 6 09/02/2026 16:55:42
1839 Elevator Failure KCEMSC missing from TTS-1 6 09/02/2026 16:55:34
4018 Elevator Failure KCEAPM has no connection to KCECPU 6 02/03/2026 16:01:50
1002 Elevator Failure Serial communication broken on board (TTS-1) 4 02/02/2026 16:10:56
1031 Elevator Failure Safety circuit: Landing door opened during drive 4 02/03/2026 14:58:23
1117 Elevator Failure KMI stop switch active 4 02/02/2026 16:06:54
1161 Elevator Failure KCEDZS board failure - Self check failed 4 02/02/2026 13:12:31
2339 Elevator Failure KCEDZS 24 V power supply failure 4 02/02/2026 13:12:25
2000 Elevator Failure Missing COP 3 02/02/2026 16:04:29
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 3 09/02/2026 08:02:06
4017 Elevator Failure KCEAPM 12V power failed (battery failure) 3 02/02/2026 17:15:11
100 Temporary Fault Unclassified Alarm 1 09/02/2026 06:54:46
101 Real Alarm Real Alarm 1 03/02/2026 14:39:33
103 False Alarm False Alarm 1 31/12/2025 11:16:19
1830 Elevator Failure LON communication error 1 21/12/2025 02:37:25