Suivi Activite Telesurveillance 43747040


Infos Telalarme
N° Transmetteur 43747040
N° Equipement 43747040
Voie
N° de ligne telephonique 882390099693455
Equipements sur la meme ligne Telephonique 43747040,
Modele et profil TS KCE - DEFAULT KONE 4G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 14:33:31
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 550
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1606 Elevator Failure Car door closing failed, too many closing trials 331 15/01/2026 16:12:41
SYSRCA Réception Appel Cyclique 90 09/03/2026 15:33:26
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 73 12/02/2026 13:45:22
1004 Elevator Failure TTS serial communication broken. One channel 50 12/02/2026 14:25:16
1099 Elevator Failure Main stop switch open 38 12/02/2026 14:32:01
1109 Elevator Failure Landing door not opened after top of car inspection 36 26/01/2026 12:51:13
1839 Elevator Failure KCEMSC missing from TTS-1 31 12/02/2026 14:25:08
1840 Elevator Failure KCEMSC missing from TTS-2 30 12/02/2026 14:25:08
1129 Elevator Failure Inspection drive unit stop button active 28 12/02/2026 14:00:49
1132 Elevator Failure Pit inspection mode reset input active too long 27 15/01/2026 11:17:56
1009 Elevator Failure Safety circuit: Emergency exit (C3) 24 15/01/2026 11:11:04
1607 Elevator Failure Reopen device active too long 21 09/03/2026 12:10:17
1117 Elevator Failure KMI stop switch active 12 26/01/2026 13:03:58
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 12 12/02/2026 22:55:04
1031 Elevator Failure Safety circuit: Landing door opened during drive 11 12/02/2026 14:33:59
1008 Elevator Failure Safety circuit: Safety gear (C2) 8 12/02/2026 14:25:53
1030 Elevator Failure Safety circuit: buffer contact or OSG contact (H2) 8 12/02/2026 14:26:28
1091 Elevator Failure Lift on final limit magnet 8 12/02/2026 14:39:00
1114 Elevator Failure Pit inspection mode input failure 8 15/01/2026 11:30:33
1702 Elevator Failure Start timeout 8 12/02/2026 14:37:57
1011 Elevator Failure Car door contact opened during drive (C5) 4 17/02/2026 16:55:41
102 Temporary Fault Test Alarm 4 12/02/2026 13:41:55
1703 Elevator Failure Start failed 4 15/01/2026 11:16:14
103 False Alarm False Alarm 3 08/02/2026 15:26:27
1000 Elevator Failure Serial communication broken on board (both TTS channels) 2 15/01/2026 11:14:00
1003 Elevator Failure Serial communication broken on board (TTS-2) 2 15/01/2026 11:14:01
1035 Elevator Failure Unintended movement 2 15/01/2026 08:58:57
1066 Elevator Failure TTS2 communication fault 2 26/01/2026 10:53:20
4018 Elevator Failure KCEAPM has no connection to KCECPU 2 12/02/2026 15:10:37
<-- Retour KOF