| SYSRCA |
|
Réception Appel Cyclique |
94 |
09/03/2026 21:06:57 |
|
1140 |
Elevator Failure Safety circuit: Inspection up limit
|
26 |
12/02/2026 11:01:28 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
20 |
12/02/2026 11:01:34 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
19 |
12/02/2026 11:09:18 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
19 |
12/02/2026 11:17:49 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
17 |
12/02/2026 11:06:06 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
15 |
11/02/2026 17:41:39 |
|
1117 |
Elevator Failure KMI stop switch active
|
15 |
11/02/2026 17:37:36 |
|
1023 |
Elevator Failure Car door bypass switch active
|
13 |
12/02/2026 10:20:11 |
|
1607 |
Elevator Failure Reopen device active too long
|
12 |
03/03/2026 08:33:57 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
10 |
11/02/2026 17:11:53 |
|
1702 |
Elevator Failure Start timeout
|
10 |
27/02/2026 15:32:21 |
|
1099 |
Elevator Failure Main stop switch open |
8 |
11/02/2026 17:38:27 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
6 |
11/02/2026 17:38:27 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
6 |
11/02/2026 17:37:37 |
|
1004 |
Elevator Failure TTS serial communication broken. One channel
|
5 |
11/02/2026 17:12:09 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
4 |
11/02/2026 16:26:46 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
4 |
11/02/2026 17:37:37 |
|
1190 |
Elevator Failure Device picked input dropped while lift running
|
3 |
11/02/2026 16:30:51 |
|
102 |
Temporary Fault Test Alarm |
2 |
11/02/2026 16:52:15 |
|
1703 |
Elevator Failure Start failed
|
2 |
13/02/2026 15:36:31 |
|
103 |
False Alarm False Alarm |
1 |
14/02/2026 22:09:34 |