| SYSRCA |
|
Réception Appel Cyclique |
97 |
09/03/2026 14:15:48 |
|
4018 |
Elevator Failure KCEAPM has no connection to KCECPU
|
8 |
15/02/2026 13:06:41 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
4 |
12/12/2025 15:32:17 |
|
1607 |
Elevator Failure Reopen device active too long
|
4 |
27/02/2026 07:38:08 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
2 |
09/02/2026 09:48:14 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
12/12/2025 12:26:28 |
|
101 |
Real Alarm Real Alarm |
1 |
12/12/2025 11:21:12 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
1 |
09/02/2026 09:47:11 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
1 |
09/02/2026 09:48:48 |
|
1830 |
Elevator Failure LON communication error
|
1 |
31/01/2026 04:28:49 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
1 |
31/01/2026 04:29:03 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
1 |
31/01/2026 04:29:03 |