Suivi Activite Telesurveillance 43764752


Infos Telalarme
N° Transmetteur 43764752
N° Equipement 43764752
Voie
N° de ligne telephonique 882397120940090
Equipements sur la meme ligne Telephonique 43764752,
Modele et profil TS KCE - DEFAULT KONE 3G
Statut TS OK
Controle des appels cycliques automatiques Actif
Date de creation CCC
Date dernier appel recu au CCC 09/03/2026 19:01:59
Derniere consigne KC3
du au
Nombre d'appels recus sur les 3 derniers mois 253
Option contrat "Lien vocal" Inclus service et com mobile
 24/7 CLOUDVIEW
Pour acceder au detail des evenements recus, cliquer ici
Type Evenement Type alarme Nbre evenements recus sur les 3 derniers mois Date dernier evenement recu
1039 Elevator Failure Door open monitoring functioned 101 26/02/2026 09:07:51
SYSRCA Réception Appel Cyclique 94 09/03/2026 20:01:54
1029 Elevator Failure Safety circuit: Pit safety contact open (H1) 45 26/02/2026 09:06:59
1033 Elevator Failure safety circuit: Buffers supervision. Up input failure 44 26/02/2026 09:01:00
1109 Elevator Failure Landing door not opened after top of car inspection 25 26/02/2026 08:58:56
4017 Elevator Failure KCEAPM 12V power failed (battery failure) 23 24/02/2026 15:47:05
1141 Elevator Failure Safety circuit: Inspection down limit 20 20/02/2026 14:46:44
4018 Elevator Failure KCEAPM has no connection to KCECPU 13 22/01/2026 08:38:40
1117 Elevator Failure KMI stop switch active 12 26/02/2026 08:48:35
1004 Elevator Failure TTS serial communication broken. One channel 11 26/02/2026 08:57:55
1068 Elevator Failure 24V power supply voltage out of +- 20 % range 10 26/02/2026 08:50:46
1839 Elevator Failure KCEMSC missing from TTS-1 9 26/02/2026 08:57:46
1099 Elevator Failure Main stop switch open 8 26/02/2026 08:50:46
1132 Elevator Failure Pit inspection mode reset input active too long 8 20/02/2026 15:09:52
1181 Elevator Failure Door bypass switch misuse 8 20/02/2026 14:47:00
1024 Elevator Failure Hoistway door bypass switch active 6 20/02/2026 14:45:35
1129 Elevator Failure Inspection drive unit stop button active 6 26/02/2026 09:01:55
1840 Elevator Failure KCEMSC missing from TTS-2 5 26/02/2026 08:57:46
1023 Elevator Failure Car door bypass switch active 4 20/02/2026 14:45:36
1082 Elevator Failure KCEMSC board failure - Comparison of KCEFUI inputs 4 20/02/2026 14:45:32
102 Temporary Fault Test Alarm 2 28/01/2026 09:34:38
1830 Elevator Failure LON communication error 2 21/01/2026 17:28:19
200 System failure: KCE System failure: KCE 2 24/02/2026 16:17:28
1056 Elevator Failure Movement risk during start or stop sequence (motor movement) counter 1 17/02/2026 09:29:19
4016 Elevator Failure KCEAPM 24V power failed (mains missing) 1 20/02/2026 16:18:19
<-- Retour KOF