| SYSRCA |
|
Réception Appel Cyclique |
93 |
09/03/2026 13:42:53 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
18/02/2026 14:35:15 |
|
1011 |
Elevator Failure Car door contact opened during drive (C5)
|
4 |
18/02/2026 14:39:21 |
|
1024 |
Elevator Failure Hoistway door bypass switch active
|
4 |
18/02/2026 14:40:25 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
4 |
18/02/2026 14:39:21 |
|
1830 |
Elevator Failure LON communication error
|
2 |
11/01/2026 16:40:47 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
2 |
11/01/2026 16:41:04 |
|
1840 |
Elevator Failure KCEMSC missing from TTS-2
|
2 |
11/01/2026 16:41:04 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
2 |
18/02/2026 15:41:26 |
|
102 |
Temporary Fault Test Alarm |
1 |
11/12/2025 11:03:43 |
|
103 |
False Alarm False Alarm |
1 |
18/02/2026 14:37:14 |