| SYSRCA |
|
Réception Appel Cyclique |
103 |
09/03/2026 04:20:08 |
|
1129 |
Elevator Failure Inspection drive unit stop button active
|
16 |
12/02/2026 15:15:38 |
|
1029 |
Elevator Failure Safety circuit: Pit safety contact open (H1) |
15 |
12/02/2026 15:20:14 |
|
1099 |
Elevator Failure Main stop switch open |
15 |
12/02/2026 14:59:09 |
|
1091 |
Elevator Failure Lift on final limit magnet
|
12 |
12/02/2026 14:59:09 |
|
1068 |
Elevator Failure 24V power supply voltage out of +- 20 % range
|
11 |
12/02/2026 14:59:09 |
|
1031 |
Elevator Failure Safety circuit: Landing door opened during drive
|
10 |
12/02/2026 15:13:29 |
|
1030 |
Elevator Failure Safety circuit: buffer contact or OSG contact (H2) |
8 |
12/02/2026 15:06:11 |
|
1607 |
Elevator Failure Reopen device active too long
|
6 |
27/02/2026 12:26:31 |
|
1109 |
Elevator Failure Landing door not opened after top of car inspection
|
5 |
23/12/2025 15:18:14 |
|
1008 |
Elevator Failure Safety circuit: Safety gear (C2)
|
4 |
12/02/2026 15:02:36 |
|
1010 |
Elevator Failure Safety circuit: blocking device (C4)
|
4 |
12/02/2026 15:12:19 |
|
1117 |
Elevator Failure KMI stop switch active
|
4 |
22/12/2025 08:18:19 |
|
4016 |
Elevator Failure KCEAPM 24V power failed (mains missing)
|
4 |
27/01/2026 01:13:56 |
|
1702 |
Elevator Failure Start timeout
|
2 |
22/12/2025 08:01:59 |
|
103 |
False Alarm False Alarm |
1 |
12/02/2026 14:54:52 |
|
1839 |
Elevator Failure KCEMSC missing from TTS-1
|
1 |
23/12/2025 15:28:08 |